Back to control gear ↗- 3RU2126-1FB0SIRIUS 3RU2 thermal overload relay, 3.5–5 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2126-1GB0SIRIUS 3RU2 thermal overload relay, 4.5–6.3 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2126-1HB0SIRIUS 3RU2 thermal overload relay, 5.5–8 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2126-1JB0SIRIUS 3RU2 thermal overload relay, 7–10 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2126-1KB0SIRIUS 3RU2 thermal overload relay, 9–12.5 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2126-4AB0SIRIUS 3RU2 thermal overload relay, 11–16 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2126-4BB0SIRIUS 3RU2 thermal overload relay, 14–20 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2126-4CB0SIRIUS 3RU2 thermal overload relay, 17–22 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2126-4DB0SIRIUS 3RU2 thermal overload relay, 20–25 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2126-4NB0SIRIUS 3RU2 thermal overload relay, 23–28 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2126-4EB0SIRIUS 3RU2 thermal overload relay, 27–32 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2126-4PB0SIRIUS 3RU2 thermal overload relay, 30–36 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2126-4FB0SIRIUS 3RU2 thermal overload relay, 34–40 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2136-1HB0SIRIUS 3RU2 thermal overload relay, 5.5–8 A, size S2, CLASS 10, screw terminals. Direct mounting to matching 3RT203 contactor; separate mounting support available.
- 3RU2136-1JB0SIRIUS 3RU2 thermal overload relay, 7–10 A, size S2, CLASS 10, screw terminals. Direct mounting to matching 3RT203 contactor; separate mounting support available.
- 3RU2136-1KB0SIRIUS 3RU2 thermal overload relay, 9–12.5 A, size S2, CLASS 10, screw terminals. Direct mounting to matching 3RT203 contactor; separate mounting support available.
- 3RU2136-4AB0SIRIUS 3RU2 thermal overload relay, 11–16 A, size S2, CLASS 10, screw terminals. Direct mounting to matching 3RT203 contactor; separate mounting support available.
- 3RU2136-4BB0SIRIUS 3RU2 thermal overload relay, 14–20 A, size S2, CLASS 10, screw terminals. Direct mounting to matching 3RT203 contactor; separate mounting support available.
- 3RU2136-4DB0SIRIUS 3RU2 thermal overload relay, 18–25 A, size S2, CLASS 10, screw terminals. Direct mounting to matching 3RT203 contactor; separate mounting support available.
- 3RU2136-4EB0SIRIUS 3RU2 thermal overload relay, 22–32 A, size S2, CLASS 10, screw terminals. Direct mounting to matching 3RT203 contactor; separate mounting support available.
- 3RU2136-4FB0SIRIUS 3RU2 thermal overload relay, 28–40 A, size S2, CLASS 10, screw terminals. Direct mounting to matching 3RT203 contactor; separate mounting support available.
- 3RU2136-4GB0SIRIUS 3RU2 thermal overload relay, 36–45 A, size S2, CLASS 10, screw terminals. Direct mounting to matching 3RT203 contactor; separate mounting support available.
- 3RU2136-4HB0SIRIUS 3RU2 thermal overload relay, 40–50 A, size S2, CLASS 10, screw terminals. Direct mounting to matching 3RT203 contactor; separate mounting support available.
- 3RU2136-4QB0SIRIUS 3RU2 thermal overload relay, 47–57 A, size S2, CLASS 10, screw terminals. Direct mounting to matching 3RT203 contactor; separate mounting support available.
- 3RU2136-4JB0SIRIUS 3RU2 thermal overload relay, 54–65 A, size S2, CLASS 10, screw terminals. Direct mounting to matching 3RT203 contactor; separate mounting support available.
- 3RU2136-4KB0SIRIUS 3RU2 thermal overload relay, 62–73 A, size S2, CLASS 10A, screw terminals. Direct mounting to matching 3RT203 contactor; separate mounting support available.
- 3RU2136-4RB0SIRIUS 3RU2 thermal overload relay, 70–80 A, size S2, CLASS 10A, screw terminals. Direct mounting to matching 3RT203 contactor; separate mounting support available.
- 3RU2146-4FB0SIRIUS 3RU2 thermal overload relay, 28–40 A, size S3, CLASS 10, screw terminals. Direct mounting to matching 3RT204 contactor; separate mounting support available.
- 3RU2146-4HB0SIRIUS 3RU2 thermal overload relay, 36–50 A, size S3, CLASS 10, screw terminals. Direct mounting to matching 3RT204 contactor; separate mounting support available.
- 3RU2146-4JB0SIRIUS 3RU2 thermal overload relay, 45–63 A, size S3, CLASS 10, screw terminals. Direct mounting to matching 3RT204 contactor; separate mounting support available.
- 3RU2146-4KB0SIRIUS 3RU2 thermal overload relay, 57–75 A, size S3, CLASS 10, screw terminals. Direct mounting to matching 3RT204 contactor; separate mounting support available.
- 3RU2146-4LB0SIRIUS 3RU2 thermal overload relay, 70–90 A, size S3, CLASS 10, screw terminals. Direct mounting to matching 3RT204 contactor; separate mounting support available.
- 3RU2146-4MB0SIRIUS 3RU2 thermal overload relay, 80–100 A, size S3, CLASS 10, screw terminals. Direct mounting to matching 3RT204 contactor; separate mounting support available.
- 3RU2916-3AA01SIRIUS 3RU2 terminal support, size S00, for separate screw or DIN rail mounting of matching screw-terminal overload relays.
- 3RU2926-3AA01SIRIUS 3RU2 terminal support, size S0, for separate screw or DIN rail mounting of matching screw-terminal overload relays.
- 3RU2936-3AA01SIRIUS 3RU2 terminal support, size S2, for separate screw or DIN rail mounting of matching screw-terminal overload relays.
- 3RU2946-3AA01SIRIUS 3RU2 terminal support, size S3, for separate screw or DIN rail mounting of matching screw-terminal overload relays.
- 3RW3013-1BB04SIRIUS 3RW30 soft starter, 1.5 kW at 400 V, 3.6 A at 40°C, 24 V AC/DC control supply. Separate motor overload protection required.
- 3RW3013-1BB14SIRIUS 3RW30 soft starter, 1.5 kW at 400 V, 3.6 A at 40°C, 110–230 V AC/DC control supply. Separate motor overload protection required.
- 3RW3014-1BB04SIRIUS 3RW30 soft starter, 3 kW at 400 V, 6.5 A at 40°C, 24 V AC/DC control supply. Separate motor overload protection required.
- 3RW3014-1BB14SIRIUS 3RW30 soft starter, 3 kW at 400 V, 6.5 A at 40°C, 110–230 V AC/DC control supply. Separate motor overload protection required.
- 3RW3016-1BB04SIRIUS 3RW30 soft starter, 4 kW at 400 V, 9 A at 40°C, 24 V AC/DC control supply. Separate motor overload protection required.
- 3RW3016-1BB14SIRIUS 3RW30 soft starter, 4 kW at 400 V, 9 A at 40°C, 110–230 V AC/DC control supply. Separate motor overload protection required.
- 3RW3017-1BB04SIRIUS 3RW30 soft starter, 5.5 kW at 400 V, 12.5 A at 40°C, 24 V AC/DC control supply. Separate motor overload protection required.
- 3RW3017-1BB14SIRIUS 3RW30 soft starter, 5.5 kW at 400 V, 12.5 A at 40°C, 110–230 V AC/DC control supply. Separate motor overload protection required.
- 3RW3018-1BB04SIRIUS 3RW30 soft starter, 7.5 kW at 400 V, 17.6 A at 40°C, 24 V AC/DC control supply. Separate motor overload protection required.
- 3RW3018-1BB14SIRIUS 3RW30 soft starter, 7.5 kW at 400 V, 17.6 A at 40°C, 110–230 V AC/DC control supply. Separate motor overload protection required.
- 3RW4024-1BB04SIRIUS 3RW40 soft starter, 5.5 kW at 400 V, 12.5 A at 40°C, 24 V AC/DC control supply. Integrated motor overload protection.