Siemens SENTRON 3VA10/11 terminal cover
3VA9111-0WD40
SENTRON 3VA10/11 terminal cover, 4 pole, one cover.
- Application
- Moulded case circuit breakers
- Accessory type
- Terminal covers
- Option
- 4 pole · frame 100/160

Product specification
3VA9111-0WD40
SENTRON 3VA10/11 terminal cover, 4 pole, one cover.
Dimensions & specifications
Accessories are matched to individual parts. A shared manufacturer or frame size alone does not establish compatibility.
Accessories & related parts
3VA9111-0WD40 — specifications & documents
SENTRON 3VA10/11 terminal cover, 4 pole, one cover.
| Accessory type | Terminal covers |
|---|---|
| Cover poles | 4 |
| Suitable frame | 3VA10/11 |
| Supply unit | 1 cover |
Fits these parts
- 3VA1140-4EF46-0AA0 SENTRON 3VA1 frame 160 moulded case circuit breaker, 40 A, 4 pole, 36 kA at 415 V. TM240 adjustable thermal/magnetic protection, box terminals. Switched neutral is unprotected.
- 3VA1140-5EF46-0AA0 SENTRON 3VA1 frame 160 moulded case circuit breaker, 40 A, 4 pole, 55 kA at 415 V. TM240 adjustable thermal/magnetic protection, box terminals. Switched neutral is unprotected.
- 3VA1163-4EF46-0AA0 SENTRON 3VA1 frame 160 moulded case circuit breaker, 63 A, 4 pole, 36 kA at 415 V. TM240 adjustable thermal/magnetic protection, box terminals. Switched neutral is unprotected.
- 3VA1163-5EF46-0AA0 SENTRON 3VA1 frame 160 moulded case circuit breaker, 63 A, 4 pole, 55 kA at 415 V. TM240 adjustable thermal/magnetic protection, box terminals. Switched neutral is unprotected.
- 3VA1110-4EF46-0AA0 SENTRON 3VA1 frame 160 moulded case circuit breaker, 100 A, 4 pole, 36 kA at 415 V. TM240 adjustable thermal/magnetic protection, box terminals. Switched neutral is unprotected.
- 3VA1110-5EF46-0AA0 SENTRON 3VA1 frame 160 moulded case circuit breaker, 100 A, 4 pole, 55 kA at 415 V. TM240 adjustable thermal/magnetic protection, box terminals. Switched neutral is unprotected.
- 3VA1112-4EF46-0AA0 SENTRON 3VA1 frame 160 moulded case circuit breaker, 125 A, 4 pole, 36 kA at 415 V. TM240 adjustable thermal/magnetic protection, box terminals. Switched neutral is unprotected.
- 3VA1112-5EF46-0AA0 SENTRON 3VA1 frame 160 moulded case circuit breaker, 125 A, 4 pole, 55 kA at 415 V. TM240 adjustable thermal/magnetic protection, box terminals. Switched neutral is unprotected.
- 3VA1116-4EF46-0AA0 SENTRON 3VA1 frame 160 moulded case circuit breaker, 160 A, 4 pole, 36 kA at 415 V. TM240 adjustable thermal/magnetic protection, box terminals. Switched neutral is unprotected.