Thermal Overload Relays
Select the manufacturer, relay range and motor current setting. Contactor pages show matched overload relays.

Product specification
3RU2116-1HB0
SIRIUS 3RU2 thermal overload relay, 5.5–8 A, size S00, CLASS 10, screw terminals. Direct mounting to matching 3RT201 contactor; separate mounting support available.
Dimensions & specifications
Choose the relay that fits the selected contactor and set it to the motor nameplate current. Frame compatibility is shown on each product.
Accessories & related parts
Search part numbers & specifications
Open to search 129 parts.
Browse part numbers (97)
- TF42-0.13TF42 thermal overload relay, 0.1–0.13 A, trip class 10. Direct mounting on AF09, AF12, AF16, AF26, AF30, AF38 contactors.
- TF42-0.17TF42 thermal overload relay, 0.13–0.17 A, trip class 10. Direct mounting on AF09, AF12, AF16, AF26, AF30, AF38 contactors.
- TF42-0.23TF42 thermal overload relay, 0.17–0.23 A, trip class 10. Direct mounting on AF09, AF12, AF16, AF26, AF30, AF38 contactors.
- TF42-0.31TF42 thermal overload relay, 0.23–0.31 A, trip class 10. Direct mounting on AF09, AF12, AF16, AF26, AF30, AF38 contactors.
- TF42-0.41TF42 thermal overload relay, 0.31–0.41 A, trip class 10. Direct mounting on AF09, AF12, AF16, AF26, AF30, AF38 contactors.
- TF42-0.55TF42 thermal overload relay, 0.41–0.55 A, trip class 10. Direct mounting on AF09, AF12, AF16, AF26, AF30, AF38 contactors.
- TF42-0.74TF42 thermal overload relay, 0.55–0.74 A, trip class 10. Direct mounting on AF09, AF12, AF16, AF26, AF30, AF38 contactors.
- TF42-1.0TF42 thermal overload relay, 0.74–1 A, trip class 10. Direct mounting on AF09, AF12, AF16, AF26, AF30, AF38 contactors.
- TF42-1.3TF42 thermal overload relay, 1–1.3 A, trip class 10. Direct mounting on AF09, AF12, AF16, AF26, AF30, AF38 contactors.
- TF42-1.7TF42 thermal overload relay, 1.3–1.7 A, trip class 10. Direct mounting on AF09, AF12, AF16, AF26, AF30, AF38 contactors.
- TF42-2.3TF42 thermal overload relay, 1.7–2.3 A, trip class 10. Direct mounting on AF09, AF12, AF16, AF26, AF30, AF38 contactors.
- TF42-3.1TF42 thermal overload relay, 2.3–3.1 A, trip class 10. Direct mounting on AF09, AF12, AF16, AF26, AF30, AF38 contactors.
- TF42-4.2TF42 thermal overload relay, 3.1–4.2 A, trip class 10. Direct mounting on AF09, AF12, AF16, AF26, AF30, AF38 contactors.
- TF42-5.7TF42 thermal overload relay, 4.2–5.7 A, trip class 10. Direct mounting on AF09, AF12, AF16, AF26, AF30, AF38 contactors.
- TF42-7.6TF42 thermal overload relay, 5.7–7.6 A, trip class 10. Direct mounting on AF09, AF12, AF16, AF26, AF30, AF38 contactors.
- TF42-10TF42 thermal overload relay, 7.6–10 A, trip class 10. Direct mounting on AF09, AF12, AF16, AF26, AF30, AF38 contactors.
- TF42-13TF42 thermal overload relay, 10–13 A, trip class 10. Direct mounting on AF09, AF12, AF16, AF26, AF30, AF38 contactors.
- TF42-16TF42 thermal overload relay, 13–16 A, trip class 10. Direct mounting on AF09, AF12, AF16, AF26, AF30, AF38 contactors.
- TF42-20TF42 thermal overload relay, 16–20 A, trip class 10. Direct mounting on AF09, AF12, AF16, AF26, AF30, AF38 contactors.
- TF42-24TF42 thermal overload relay, 20–24 A, trip class 10. Direct mounting on AF09, AF12, AF16, AF26, AF30, AF38 contactors.
- TF42-29TF42 thermal overload relay, 24–29 A, trip class 10. Direct mounting on AF09, AF12, AF16, AF26, AF30, AF38 contactors.
- TF42-35TF42 thermal overload relay, 29–35 A, trip class 10. Direct mounting on AF09, AF12, AF16, AF26, AF30, AF38 contactors.
- TF42-38TF42 thermal overload relay, 35–38 A, trip class 10. Direct mounting on AF09, AF12, AF16, AF26, AF30, AF38 contactors.
- TF65-28TF65 thermal overload relay, 22–28 A, trip class 10. Direct mounting on AF40, AF52, AF65 contactors.
- TF65-33TF65 thermal overload relay, 25–33 A, trip class 10. Direct mounting on AF40, AF52, AF65 contactors.
- TF65-40TF65 thermal overload relay, 30–40 A, trip class 10. Direct mounting on AF40, AF52, AF65 contactors.
- TF65-47TF65 thermal overload relay, 36–47 A, trip class 10. Direct mounting on AF40, AF52, AF65 contactors.
- TF65-53TF65 thermal overload relay, 44–53 A, trip class 10. Direct mounting on AF40, AF52, AF65 contactors.
- TF65-60TF65 thermal overload relay, 50–60 A, trip class 10. Direct mounting on AF40, AF52, AF65 contactors.
- TF65-67TF65 thermal overload relay, 57–67 A, trip class 10. Direct mounting on AF40, AF52, AF65 contactors.
- TF96-51TF96 thermal overload relay, 40–51 A, trip class 10. Direct mounting on AF80, AF96 contactors.
- TF96-60TF96 thermal overload relay, 48–60 A, trip class 10. Direct mounting on AF80, AF96 contactors.
- TF96-68TF96 thermal overload relay, 57–68 A, trip class 10. Direct mounting on AF80, AF96 contactors.
- TF96-78TF96 thermal overload relay, 65–78 A, trip class 10. Direct mounting on AF80, AF96 contactors.
- TF96-87TF96 thermal overload relay, 75–87 A, trip class 10. Direct mounting on AF80, AF96 contactors.
- TF96-96TF96 thermal overload relay, 84–96 A, trip class 10. Direct mounting on AF80, AF96 contactors.
- TF140DU-90TF140DU thermal overload relay, 66–90 A, trip class 10A. Direct mounting on AF116, AF140 contactors.
- TF140DU-110TF140DU thermal overload relay, 80–110 A, trip class 10A. Direct mounting on AF116, AF140 contactors.
- TF140DU-135TF140DU thermal overload relay, 100–135 A, trip class 10A. Direct mounting on AF116, AF140 contactors.
- TF140DU-142TF140DU thermal overload relay, 110–142 A, trip class 10A. Direct mounting on AF116, AF140 contactors.
- 3RU2116-0AB0SIRIUS 3RU2 thermal overload relay, 0.11–0.16 A, size S00, CLASS 10, screw terminals. Direct mounting to matching 3RT201 contactor; separate mounting support available.
- 3RU2116-0BB0SIRIUS 3RU2 thermal overload relay, 0.14–0.2 A, size S00, CLASS 10, screw terminals. Direct mounting to matching 3RT201 contactor; separate mounting support available.
- 3RU2116-0CB0SIRIUS 3RU2 thermal overload relay, 0.18–0.25 A, size S00, CLASS 10, screw terminals. Direct mounting to matching 3RT201 contactor; separate mounting support available.
- 3RU2116-0DB0SIRIUS 3RU2 thermal overload relay, 0.22–0.32 A, size S00, CLASS 10, screw terminals. Direct mounting to matching 3RT201 contactor; separate mounting support available.
- 3RU2116-0EB0SIRIUS 3RU2 thermal overload relay, 0.28–0.4 A, size S00, CLASS 10, screw terminals. Direct mounting to matching 3RT201 contactor; separate mounting support available.
- 3RU2116-0FB0SIRIUS 3RU2 thermal overload relay, 0.35–0.5 A, size S00, CLASS 10, screw terminals. Direct mounting to matching 3RT201 contactor; separate mounting support available.
- 3RU2116-0GB0SIRIUS 3RU2 thermal overload relay, 0.45–0.63 A, size S00, CLASS 10, screw terminals. Direct mounting to matching 3RT201 contactor; separate mounting support available.
- 3RU2116-0HB0SIRIUS 3RU2 thermal overload relay, 0.55–0.8 A, size S00, CLASS 10, screw terminals. Direct mounting to matching 3RT201 contactor; separate mounting support available.
- 3RU2116-0JB0SIRIUS 3RU2 thermal overload relay, 0.7–1 A, size S00, CLASS 10, screw terminals. Direct mounting to matching 3RT201 contactor; separate mounting support available.
- 3RU2116-0KB0SIRIUS 3RU2 thermal overload relay, 0.9–1.25 A, size S00, CLASS 10, screw terminals. Direct mounting to matching 3RT201 contactor; separate mounting support available.
- 3RU2116-1AB0SIRIUS 3RU2 thermal overload relay, 1.1–1.6 A, size S00, CLASS 10, screw terminals. Direct mounting to matching 3RT201 contactor; separate mounting support available.
- 3RU2116-1BB0SIRIUS 3RU2 thermal overload relay, 1.4–2 A, size S00, CLASS 10, screw terminals. Direct mounting to matching 3RT201 contactor; separate mounting support available.
- 3RU2116-1CB0SIRIUS 3RU2 thermal overload relay, 1.8–2.5 A, size S00, CLASS 10, screw terminals. Direct mounting to matching 3RT201 contactor; separate mounting support available.
- 3RU2116-1DB0SIRIUS 3RU2 thermal overload relay, 2.2–3.2 A, size S00, CLASS 10, screw terminals. Direct mounting to matching 3RT201 contactor; separate mounting support available.
- 3RU2116-1EB0SIRIUS 3RU2 thermal overload relay, 2.8–4 A, size S00, CLASS 10, screw terminals. Direct mounting to matching 3RT201 contactor; separate mounting support available.
- 3RU2116-1FB0SIRIUS 3RU2 thermal overload relay, 3.5–5 A, size S00, CLASS 10, screw terminals. Direct mounting to matching 3RT201 contactor; separate mounting support available.
- 3RU2116-1GB0SIRIUS 3RU2 thermal overload relay, 4.5–6.3 A, size S00, CLASS 10, screw terminals. Direct mounting to matching 3RT201 contactor; separate mounting support available.
- 3RU2116-1HB0SIRIUS 3RU2 thermal overload relay, 5.5–8 A, size S00, CLASS 10, screw terminals. Direct mounting to matching 3RT201 contactor; separate mounting support available.
- 3RU2116-1JB0SIRIUS 3RU2 thermal overload relay, 7–10 A, size S00, CLASS 10, screw terminals. Direct mounting to matching 3RT201 contactor; separate mounting support available.
- 3RU2116-1KB0SIRIUS 3RU2 thermal overload relay, 9–12.5 A, size S00, CLASS 10, screw terminals. Direct mounting to matching 3RT201 contactor; separate mounting support available.
- 3RU2116-4AB0SIRIUS 3RU2 thermal overload relay, 11–16 A, size S00, CLASS 10, screw terminals. Direct mounting to matching 3RT201 contactor; separate mounting support available.
- 3RU2126-1CB0SIRIUS 3RU2 thermal overload relay, 1.8–2.5 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2126-1DB0SIRIUS 3RU2 thermal overload relay, 2.2–3.2 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2126-1EB0SIRIUS 3RU2 thermal overload relay, 2.8–4 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2126-1FB0SIRIUS 3RU2 thermal overload relay, 3.5–5 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2126-1GB0SIRIUS 3RU2 thermal overload relay, 4.5–6.3 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2126-1HB0SIRIUS 3RU2 thermal overload relay, 5.5–8 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2126-1JB0SIRIUS 3RU2 thermal overload relay, 7–10 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2126-1KB0SIRIUS 3RU2 thermal overload relay, 9–12.5 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2126-4AB0SIRIUS 3RU2 thermal overload relay, 11–16 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2126-4BB0SIRIUS 3RU2 thermal overload relay, 14–20 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2126-4CB0SIRIUS 3RU2 thermal overload relay, 17–22 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2126-4DB0SIRIUS 3RU2 thermal overload relay, 20–25 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2126-4NB0SIRIUS 3RU2 thermal overload relay, 23–28 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2126-4EB0SIRIUS 3RU2 thermal overload relay, 27–32 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2126-4PB0SIRIUS 3RU2 thermal overload relay, 30–36 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2126-4FB0SIRIUS 3RU2 thermal overload relay, 34–40 A, size S0, CLASS 10, screw terminals. Direct mounting to matching 3RT202 contactor; separate mounting support available.
- 3RU2136-1HB0SIRIUS 3RU2 thermal overload relay, 5.5–8 A, size S2, CLASS 10, screw terminals. Direct mounting to matching 3RT203 contactor; separate mounting support available.
- 3RU2136-1JB0SIRIUS 3RU2 thermal overload relay, 7–10 A, size S2, CLASS 10, screw terminals. Direct mounting to matching 3RT203 contactor; separate mounting support available.
- 3RU2136-1KB0SIRIUS 3RU2 thermal overload relay, 9–12.5 A, size S2, CLASS 10, screw terminals. Direct mounting to matching 3RT203 contactor; separate mounting support available.
- 3RU2136-4AB0SIRIUS 3RU2 thermal overload relay, 11–16 A, size S2, CLASS 10, screw terminals. Direct mounting to matching 3RT203 contactor; separate mounting support available.
- 3RU2136-4BB0SIRIUS 3RU2 thermal overload relay, 14–20 A, size S2, CLASS 10, screw terminals. Direct mounting to matching 3RT203 contactor; separate mounting support available.
- 3RU2136-4DB0SIRIUS 3RU2 thermal overload relay, 18–25 A, size S2, CLASS 10, screw terminals. Direct mounting to matching 3RT203 contactor; separate mounting support available.
- 3RU2136-4EB0SIRIUS 3RU2 thermal overload relay, 22–32 A, size S2, CLASS 10, screw terminals. Direct mounting to matching 3RT203 contactor; separate mounting support available.
- 3RU2136-4FB0SIRIUS 3RU2 thermal overload relay, 28–40 A, size S2, CLASS 10, screw terminals. Direct mounting to matching 3RT203 contactor; separate mounting support available.
- 3RU2136-4GB0SIRIUS 3RU2 thermal overload relay, 36–45 A, size S2, CLASS 10, screw terminals. Direct mounting to matching 3RT203 contactor; separate mounting support available.
- 3RU2136-4HB0SIRIUS 3RU2 thermal overload relay, 40–50 A, size S2, CLASS 10, screw terminals. Direct mounting to matching 3RT203 contactor; separate mounting support available.
- 3RU2136-4QB0SIRIUS 3RU2 thermal overload relay, 47–57 A, size S2, CLASS 10, screw terminals. Direct mounting to matching 3RT203 contactor; separate mounting support available.
- 3RU2136-4JB0SIRIUS 3RU2 thermal overload relay, 54–65 A, size S2, CLASS 10, screw terminals. Direct mounting to matching 3RT203 contactor; separate mounting support available.
- 3RU2136-4KB0SIRIUS 3RU2 thermal overload relay, 62–73 A, size S2, CLASS 10A, screw terminals. Direct mounting to matching 3RT203 contactor; separate mounting support available.
- 3RU2136-4RB0SIRIUS 3RU2 thermal overload relay, 70–80 A, size S2, CLASS 10A, screw terminals. Direct mounting to matching 3RT203 contactor; separate mounting support available.
- 3RU2146-4FB0SIRIUS 3RU2 thermal overload relay, 28–40 A, size S3, CLASS 10, screw terminals. Direct mounting to matching 3RT204 contactor; separate mounting support available.
- 3RU2146-4HB0SIRIUS 3RU2 thermal overload relay, 36–50 A, size S3, CLASS 10, screw terminals. Direct mounting to matching 3RT204 contactor; separate mounting support available.
- 3RU2146-4JB0SIRIUS 3RU2 thermal overload relay, 45–63 A, size S3, CLASS 10, screw terminals. Direct mounting to matching 3RT204 contactor; separate mounting support available.
- 3RU2146-4KB0SIRIUS 3RU2 thermal overload relay, 57–75 A, size S3, CLASS 10, screw terminals. Direct mounting to matching 3RT204 contactor; separate mounting support available.
- 3RU2146-4LB0SIRIUS 3RU2 thermal overload relay, 70–90 A, size S3, CLASS 10, screw terminals. Direct mounting to matching 3RT204 contactor; separate mounting support available.
- 3RU2146-4MB0SIRIUS 3RU2 thermal overload relay, 80–100 A, size S3, CLASS 10, screw terminals. Direct mounting to matching 3RT204 contactor; separate mounting support available.
Matching an overload relay
Choose the current setting range against the motor nameplate current, then check the matching contactor frame and mounting arrangement.
Use the selected relay datasheet to review the trip class and operating details. Contactor pages also show the matched overload options.